The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy

6Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: MRI is preferred for brain tumor assessment, while CT is used for radiotherapy simulation. This study evaluated immobilization equipment's impact on CT-MRI registration accuracy and MR image quality in RT setup. Methods: We included CT and MR images from 11 patients with high-grade glioma, all of whom were immobilized with a thermoplastic mask and headrest. T1- and T2-weighted MR images were acquired using an MR head coil in a diagnostic setup (DS) and a body matrix coil in RT setup. To assess MR image quality, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were considered in some dedicated regions of interest. We also evaluated the impact of immobilization equipment on CT-MRI rigid registration using line profile and external contour methods. Results: The CNR and SNR reduction was in the RT setup of imaging. This was more evident in T1-weighted images than in T2-weighted ones. The SNR decreased by 14.91% and 12.09%, while CNR decreased by 25.12% and 20.15% in T1- and T2-weighted images, respectively. The immobilization equipment in the RT setup decreased the mean error in rigid registration by 1.02 mm. The external contour method yielded Dice similarity coefficients (DSC) of 0.84 and 0.92 for CT-DS MRI and CT-RT MRI registration, respectively. Conclusion: The image quality reduction in the RT setup was due to the imaged region's anatomy and its position relative to the applied coil. Furthermore, optimizing the pulse sequence is crucial for MR imaging in RT applications. Although the use of immobilization equipment may decrease the image quality in the RT setup, it does not affect organ delineation, and the image quality is still satisfactory for this purpose. Also, the use of immobilization equipment in the RT setup has increased registration accuracy.

Cite

CITATION STYLE

APA

Rostami, A., Robatjazi, M., Javadinia, S. A., Shomoossi, N., & Shahraini, R. (2024). The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy. Journal of Applied Clinical Medical Physics, 25(2). https://doi.org/10.1002/acm2.14162

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free