Failure analysis of 600 MW supercritical boiler water wall

0Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Boiler tube often causes abnormal boiler outage, bringing greater economic losses. This thesis mainly comes from the dynamics of boiler water, boiler furnace accident location of wall temperature distribution to explore the cause of the accident boiler. Calculation results show that the deformation will seriously reduce the boiler allowable maximum temperature difference between the screens. And the boiler is not over-temperature, low temperature difference between the screens, which have burst pipe. Analysis of the deformation of the boiler and propose solutions. © Maxwell Scientific Organization, 2013.

Cite

CITATION STYLE

APA

Huilin, F., Zhengchun, C., Xiaozhong, Y., Jinqiao, H., & Yucai, Z. (2013). Failure analysis of 600 MW supercritical boiler water wall. Research Journal of Applied Sciences, Engineering and Technology, 6(10), 1726–1731. https://doi.org/10.19026/rjaset.6.3895