Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

5Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

Objective-To describe CT image reconstruction criteria for measurement of the tibial tuberosity-trochlear groove (TT-TG) offset distance, evaluate intra- and inter-reconstruction repeatability, and identify key sources of error in the measurement technique, as determined in vulpine hind limbs. Animals-12 red fox (Vulpes vulpes) cadavers. Procedures-CT images of each hind limb in intact cadavers were obtained; at 1-week intervals, 3 reconstructions were performed that were based on 1 plane passing through the centers of the femoral head and medial condyle and parallel to the caudal femoral condyles, 1 plane aligned with the femoral trochlea, and a third orthogonal plane. Randomized and anonymized reconstructions were assessed for TT-TG offset distance with a singleimage technique by 1 observer, and inter-reconstruction repeatability and intra- and interreconstruction measurement repeatability were assessed via the repeatability coefficient and intraclass correlation coefficient. Results-Multiplanar reconstructions of hind limb images were repeatedly made to within a few degrees of each other. Intra- and inter-reconstruction repeatability for TT-TG offset distance measurement was good. Repeatability was most affected by accurate identification of the tibial tuberosity and femoral trochlea landmarks. Conclusions and Clinical Relevance-Results obtained from vulpine hind limb CT images indicated that reconstructions can be made with a high degree of repeatability when based on strictly defined and applied criteria. The TT-TG offset distance has potential as an objective assessment of alignment of the distal portion of the quadriceps mechanism; its use as an aid in case selection for corrective femoral osteotomy among dogs with medial patellar luxation warrants investigation. (Am J Vet Res 2013;74:888-894).

Cite

CITATION STYLE

APA

Miles, J. E., Jensen, B. R., Kirpensteijn, J., Svalastoga, E. L., & Eriksen, T. (2013). Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers. American Journal of Veterinary Research, 74(6), 888–894. https://doi.org/10.2460/ajvr.74.6.888

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free