Non-Contrast-Enhanced MR Portography With Time-Spatial Labeling Inversion Pulses: Comparison of Imaging With Three-Dimensional Half-Fourier Fast Spin-Echo and True Steady-State Free-Precession Sequences

46Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To compare and evaluate images acquired with two different MR angiography (MRA) sequences, three-di- mensional (3D) half-Fourier fast spin-echo (FSE) and 3D true steady-state free-precession (SSFP) combined with two time-spatial labeling inversion pulses (T-SLIPs), for selective and non-contrast-enhanced (non-CE) visualiza- tion of the portal vein. Materials and Methods: Twenty healthy volunteers were examined using half-Fourier FSE and true SSFP sequences on a 1.5T MRI system with two T-SLIPs, one placed on the liver and thorax, and the other on the lower abdomen. For quantitative analysis, vessel-to-liver contrast (Cv-l) ratios of the main portal vein (MPV), right portal vein (RPV), and left portal vein (LPV) were measured. The quality of visualiza- tion was also evaluated. Results: In both pulse sequences, selective visualization of the portal vein was successfully conducted in all 20 volun- teers. Quantitative evaluation showed significantly better Cv-l at the RPVs and LPVs in half-Fourier FSE (P 0.0001). At the MPV, Cv-l was better in true SSFP, but was not statistically different. Visualization scores were signifi- cantly better only at branches of segments four and eight for half-Fourier FSE (P 0.001 and 0.03, respectively). Conclusion: Both 3D half-Fourier FSE and true SSFP scans with T-SLIPs enabled selective non-CE visualization of the portal vein. Half-Fourier FSE was considered appropriate for intrahepatic portal vein visualization, and true SSFP may be preferable when visualization of the MPV is required. © 2009.

Cite

CITATION STYLE

APA

Shimada, K., Isoda, H., Okada, T., Kamae, T., Arizono, S., Hirokawa, Y., … Togashi, K. (2009). Non-Contrast-Enhanced MR Portography With Time-Spatial Labeling Inversion Pulses: Comparison of Imaging With Three-Dimensional Half-Fourier Fast Spin-Echo and True Steady-State Free-Precession Sequences. Journal of Magnetic Resonance Imaging, 29(5), 1140–1146. https://doi.org/10.1002/jmri.21753

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free