Abstract
The conventional approach to cardiac magnetic resonance (CMR) involving breath holds, electrocardiography-gating, and acquisition of a short-Axis (SAX) image stack, introduces technical and logistical challenges for assessing exercise left ventricular (LV) function. Realtime, free-breathing CMR acquisition of long-Axis (LAX) images overcomes these issues and also enables assessment of global longitudinal strain (GLS). We evaluated the reliability of a free-breathing LAX approach compared to the standard SAX approach and the reproducibility of free-breathing LAX. LV SAX (contiguous stack) and LAX (two-chamber and four-chamber) 3T CMR cine images were acquired four times within one scan in 32 women with cardiovascular risk factors (56±10 years, 28±4 kg/m2) as follows: 1) resting, gated-segmented, end-expiration breath-hold; 2) resting, real-Time, free-breathing; 3) test-retest set of resting, real-Time, free-breathing; 4) peak exercise (incremental-To-maximum, in-magnet, stepper test), real-Time, free-breathing. A second scan was performed within one week in a subset (n = 5) to determine reproducibility of peak exercise measures. Reliability and agreement of the free-breathing LAX approach with the conventional SAX approach were assessed by intraclass correlation coefficient (ICC) and Bland-Altman plots, respectively. Normal control GLS reserve was also acquired in a separate set of 12 young, healthy control women (25±4 years, 22±2 kg/m2) for comparison. Comparisons of LV volumes and function among all techniques at rest had good-To-excellent reliability (ICC = 0.80 0.96), and excellent reliability between peak exercise free-breathing LAX and SAX evaluations (ICC = 0.92 0.96). Higher resting heart rates with free-breathing acquisitions compared to breath-hold (mean difference, limits of agreement: 5, 1 12 beats per minute) reduced reliability for cardiac output (ICC = 0.67 0.79). Reproducibility of the free-breathing LAX approach was good-To-excellent at rest and peak exercise (ICC = 0.74 0.99). GLS exercise reserve was impaired in older women at cardiovascular risk compared to young healthy women (-4.7 ±2.3% vs-7.4±2.1%, p = 0.001). Real-Time, free-breathing CMR with LAX evaluation provides a reliable and reproducible method to assess rest and peak exercise cardiac function, including GLS.
Cite
CITATION STYLE
Kirkham, A. A., Goonasekera, M. V., Mattiello, B. C., Grenier, J. G., Haykowsky, M. J., & Thompson, R. B. (2021, February 1). Reliability and reproducibility of cardiac MRI quantification of peak exercise function with long-Axis views. PLoS ONE. Public Library of Science. https://doi.org/10.1371/journal.pone.0245912
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.