Evaluation of sensitivity of remote field eddy current testing and low-frequency eddy current testing for inspecting grooves of metal plate

9Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

We compare remote field eddy current testing and low-frequency eddy current testing from the viewpoint of sensitivity to back-side grooves in a metal plate. We carry out experiments using three metal plates with different depths of artificial grooves. A U-shape magnetic shield gives rise to a remote field eddy current as occurs in pipe inspection. The experiments show that the two methods have almost the same sensitivity to back-side grooves if a relatively low frequency and relatively far coil interval are used, which is also validated by three-dimensional finite-element simulations. We conduct numerical investigations to find the reason for this condition. © 2012 The Japan Institute of Metals.

Cite

CITATION STYLE

APA

Wang, J., Yusa, N., Pan, H., Takagi, T., & Hashizume, H. (2013). Evaluation of sensitivity of remote field eddy current testing and low-frequency eddy current testing for inspecting grooves of metal plate. Materials Transactions, 54(1), 90–95. https://doi.org/10.2320/matertrans.M2012323