Evaluation of a portable artificial vision device among patients with low vision

32Citations
Citations of this article
100Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

IMPORTANCE Low vision is irreversible in many patients and constitutes a disability. When no treatment to improve vision is available, technological developments aid these patients in their daily lives. OBJECTIVE To evaluate the usefulness of a portable artificial vision device (OrCam) for patients with low vision. DESIGN, SETTING, AND PARTICIPANTS A prospective pilot studywas conducted between July 1 and September 30, 2015, in a US ophthalmology department among 12 patients with visual impairment and best-corrected visual acuity of 20/200 or worse in their better eye. INTERVENTIONS A 10-item test simulating activities of daily living was used to evaluate patients' functionality in 3 scenarios: using their best-corrected visual acuity with no low-vision aids, using low-vision aids if available, and using the portable artificial vision device. This 10-item test was devised for this study and is nonvalidated. The portable artificial vision device was tested at the patients' first visit and after 1 week of use at home. MAIN OUTCOMES AND MEASURES Scores on the 10-item daily function test. RESULTS Among the 12 patients, scores on the 10-item test improved from a mean (SD) of 2.5 (1.6) using best-corrected visual acuity to 9.5 (0.5) using the portable artificial vision device at the first visit (mean difference, 7.0; 95%CI, 6.0-8.0; P < .001) and 9.8 (0.4) after 1 week (mean difference from the first visit, 7.3; 95%CI, 6.3-8.3; P < .001). Mean (SD) scores with the portable artificial vision device were also better in the 7 patients who used other low-vision aids (9.7 [0.5] vs 6.0 [2.6], respectively; mean difference, 3.7; 95%CI, 1.5-5.9; P = .01). CONCLUSIONS AND RELEVANCE When patients used a portable artificial vision device, an increase in scores on a nonvalidated 10-item test of activities of daily living was seen. Further evaluations are warranted to determine the usefulness of this device among individuals with low vision.

Cite

CITATION STYLE

APA

Moisseiev, E., & Mannis, M. J. (2016). Evaluation of a portable artificial vision device among patients with low vision. JAMA Ophthalmology, 134(7), 748–752. https://doi.org/10.1001/jamaophthalmol.2016.1000

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free