Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure

61Citations
Citations of this article
69Readers
Mendeley users who have this article in their library.

Abstract

Background: Noninvasive central blood pressure (BP) independently predicts mortality, but current methods are operator-dependent, requiring skill to obtain quality recordings. The aims of this study were first, to determine the validity of an automatic, upper arm oscillometric cuff method for estimating central BP (O CBP) by comparison with the noninvasive reference standard of radial tonometry (T CBP). Second, we determined the intratest and intertest reliability of O CBP. Methods: To assess validity, central BP was estimated by O CBP (Pulsecor R6.5B monitor) and compared with T CBP (SphygmoCor) in 47 participants free from cardiovascular disease (aged 57 ± 9 years) in supine, seated, and standing positions. Brachial mean arterial pressure (MAP) and diastolic BP (DBP) from the O CBP device were used to calibrate in both devices. Duplicate measures were recorded in each position on the same day to assess intratest reliability, and participants returned within 10 ± 7 days for repeat measurements to assess intertest reliability. Results: There was a strong intraclass correlation (ICC = 0.987, P < 0.001) and small mean difference (1.2 ± 2.2 mm Hg) for central systolic BP (SBP) determined by O CBP compared with T CBP. Ninety-six percent of all comparisons (n = 495 acceptable recordings) were within 5 mm Hg. With respect to reliability, there were strong correlations but higher limits of agreement for the intratest (ICC = 0.975, P < 0.001, mean difference 0.6 ± 4.5 mm Hg) and intertest (ICC = 0.895, P < 0.001, mean difference 4.3 ± 8.0 mm Hg) comparisons. Conclusions: Estimation of central SBP using cuff oscillometry is comparable to radial tonometry and has good reproducibility. As a noninvasive, relatively operator-independent method, O CBP may be as useful as T CBP for estimating central BP in clinical practice. © 2012 American Journal of Hypertension, Ltd.

Cite

CITATION STYLE

APA

Climie, R. E. D., Schultz, M. G., Nikolic, S. B., Ahuja, K. D. K., Fell, J. W., & Sharman, J. E. (2012). Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure. American Journal of Hypertension, 25(4), 414–420. https://doi.org/10.1038/ajh.2011.238

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free