16-27: Percutaneous Left Atrial Appendage Closure with WATCHMAN device: results from the TRAPS Registry

  • Mazzone P
  • Angelo G
  • Regazzoli D
  • et al.
N/ACitations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose of the study: The WATCHMAN device for Left Atrial Appendage occlusion (LAAO) has been found effective and non-inferior to the oral anticoagulation (OAC) in patients with atrial fibrillation, and is now adopted in clinical practice. Method used: The TRAPS registry is an observational, multicenter registry involving 4 Italian centers. Patients who underwent LAAO with WATCHMAN device were enrolled, and clinical, demographic and procedural data were collected. Summary of results: In this analysis we included 148 patients. Mean age was 73 + 8 years, 57% of patients were male, 22% had heart failure, 10% had a history of transient ischemic attack, 23% a history of ischemic stroke and 72% a history of bleeding. The baseline CHADS2 score was 2.4 + 1.3, the CHADsVASc score was 3.9 + 2.8 and the HAS-BLED score was 3.3 + 1.1. 57% of the patients were on OAC at the time of implantation. The device was successfully positioned in all patients with no or minimal (, 5mm) leakage, assessed by peri-procedural transesophageal echo. Following intra-procedural complications were reported: 2 pericardial effusions treated with pericardiocentesis, 1 device-associated thrombus formation treated with aspiration, and 1 vascular access dissection. Moreover, device embolization was reported in 1 patient early after the implantation and the device was successfully snared in the iliac bifurcation. The overall rate of adverse events within 7 days was therefore (5/148 = 3.3%). In the present experience, device size was chosen >=20% greater than the LAA diameter in 68% of patients. Comparing the first half with the second half of the study cohort, the procedure duration decreased from 89min to 64min (p , 0.0001). Conclusion: The success rate in LAAO with WATCHMAN was high, and the rate of adverse events was low.We reported an experience-related improvement in procedural duration.

Cite

CITATION STYLE

APA

Mazzone, P., Angelo, G. D., Regazzoli, D., Molon, G., Senatore, G., Saccà, S., … Bella, P. D. (2016). 16-27: Percutaneous Left Atrial Appendage Closure with WATCHMAN device: results from the TRAPS Registry. EP Europace, 18(suppl_1), i7–i7. https://doi.org/10.1093/europace/18.suppl_1.i7b

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free