Particle size and density of a slurry from ultrasonic backscattering measurements at a solid interface

12Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The pivotal experiment was performed with a setup in which a plastic cylinder was mounted on the top of a horizontal Rexolite plate and a transducer mounted directly below the cylinder; a single layer of stationary 1588-μm acrylic spheres was placed in the cylinder filled with water. Two well-separated signals were received by the transducer operating in the pulse-echo mode: (1) a signal due to the reflection from water at the interface and (2) a time-delayed signal resulting from the backscattering from the spheres of diameter D. The important observation was that the time delay was equal to 2 D/c using standard notation. A method was developed to use the FFT phase difference between the incident and scattered signals at the interface to determine the time-delay as a function of frequency, the backscattering coefficient M versus frequency, a particle size distribution, and an average value of the diameter. Experimental average diameter results are shown in the square brackets for nominal particle sizes: (1) 1588-μm acrylic spheres [1564 μm], (2) polystyrene spheres for diameters from 200 μm to 500 μm [260 μm-536 μm], (3) suspended slurry of 250-300 μm polystyrene spheres at 2.25 MHz [253 μm], (4) 794 μm [759 μm] and 1588-μm [1623 μm] Teflon spheres, (5) 1588-μm stainless steel spheres [1674 μm], and (6) suspended slurry of 250-300 μm polystyrene spheres [275 μm] at 3.5 MHz for seven volume fractions. Density and particle size measurements were obtained for the latter. For the density measurement, the FFT amplitude of the scattered signal was summed from 2 to 4 MHz for each slurry. A plot of the square root of the FFT-amplitude-sum versus the volume fraction yields a straight line, passing through the origin. A calibration of the experimental setup is obtained by fitting a straight line through the data with error bars. Thus, the volume fraction for a slurry of unknown concentration can be determined by measuring the FFT-amplitude-sum. The density of the slurry is obtained from the volume fraction. These results make it feasible to develop an online and real-time pipeline sensor to measure particle size and slurry density. © 2012 American Institute of Physics.

Cite

CITATION STYLE

APA

Greenwood, M. S. (2012, September). Particle size and density of a slurry from ultrasonic backscattering measurements at a solid interface. Review of Scientific Instruments. https://doi.org/10.1063/1.4748520

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free