Tear Strip Meniscometry and Its Clinical Application: Analysis of More Than 2000 Cases

10Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To evaluate the association of strip meniscometry tear meniscus volume measurement with signs and symptoms related to dry eye. Methods: This cross-sectional study enrolled 2234 consecutive outpatients and used dry eye symptomatology and related ocular surface examinations, including the Schirmer test, fluorescein tear film break-up time (BUT), corneal fluorescein vital staining and strip meniscometry. The strip meniscometry cut-off was estimated using a receiver operating characteristic analysis. The subjective symptoms consisted of six binarized items: dryness, fatigue, photophobia, pain, irritation, and blurring. The clinical signs were also binarized by the cut-off in each test. The presence of all signs and symptoms were then analyzed using Hayashi’s quantification theory type III analysis. Results: The mean age of the participants was 59.3 ± 17.3 years. The mean values for Schirmer test, BUT, corneal fluorescein staining, and strip meniscometry were 13.6 ± 9.6 mm, 3.1 ± 2.1 seconds, 0.40 ± 0.66, and 2.4 ± 2.7 mm, respectively. The Schirmer test was negatively correlated with age (r = –0.152; P < 0.01), whereas the BUT and strip meniscometry were not. All pairs of Schirmer test, BUT, and strip meniscometry had significant correlations, but the greatest correlation was found between BUT–strip meniscometry (r = 0.238; P < 0.01). An strip meniscometry cut-off length of 2.5 mm (area under the curve = 0.618) was calculated. Hayashi’s analysis found high similarity among the presence of signs by strip meniscometry, BUT. and corneal fluorescein staining, and three nonvisual symptoms (pain, irritation, and dryness) had a distinct similarity. Conclusions: Strip meniscometry results using the cut-off of 2.5 mm could be a useful clinical indicator for the initial screening of dry eye. Translational Relevance: This large-scale case-control study further confirmed tear strip meniscometry with the new cut-off is a useful tear function examination for dry eye; it is a 5-second noninvasive procedure and associated with clinical symptoms and corneal parameters.

Cite

CITATION STYLE

APA

Miyasaka, K., Ayaki, M., & Negishi, K. (2022). Tear Strip Meniscometry and Its Clinical Application: Analysis of More Than 2000 Cases. Translational Vision Science and Technology, 11(5). https://doi.org/10.1167/tvst.11.5.3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free