Abstract
The nondestructive three-dimensional acoustic tomography concept of the present investigation combines computerized tomography image reconstruction algorithms using acoustic diffracting waves together with depth information to produce a three-dimensional (3D) image of an underground section. The approach illuminates the underground area of interest with acoustic plane waves of frequencies 200–3000 Hz. For each transmitted pulse, the reflected-refracted signals are received by a line array of acoustic sensors located at a diametrically opposite point from the acoustic source line array. For a stratified underground medium and for a given depth, which is represented by a time delay in the received signal, a horizontal tomographic 2D image is reconstructed from the received projections. Integration of the depth dependent sequence of cross-sectional reconstructed images provides a complete three-dimensional overview of the inspected terrain. The method has been tested with an experimental system that consists of a line array of four-acoustic sources, providing plane waves, and a receiving line array of 32-acoustic sensors. The results indicate both the potential and the challenges facing the new methodology. Suggestions are made for improved performance, including an adaptive noise cancellation scheme and a numerical interpolation technique.
Cite
CITATION STYLE
Younis, W. A., Stergiopoulos, S., Havelock, D., & Grodski, J. (2002). Nondestructive imaging of shallow buried objects using acoustic computed tomography. The Journal of the Acoustical Society of America, 111(5), 2117–2127. https://doi.org/10.1121/1.1470507