Abstract
PV system modeling is primarily done on hourly timescales and so cannot capture subhourly effects, including inverter saturation. Inverter saturation occurs when the potential dc power, P dc, produced by the collectors is greater than the inverter capacity, and some of the PV power is lost or "clipped."The inverter clips power rapidly, and calculations based on hour-averaged P dc will overestimate ac power output for hours in which clipping occurs intermittently. Clipping is greater in systems with high ratios of collectors to inverter capacity, "dc:ac ratio."We studied this modeling error using minute-scale P dc measurements from a test site in Birmingham AL that had four different mounting configurations equipped with oversized inverters; i.e., 0.8 dc:ac ratio. PV output was calculated using minute- and hour-averaged P dc and modeled inverters with dc:ac ratios up to 2.0. The modeling errors due to short term inverter saturation were approximately 2% of the annual output for 1.4 dc:ac ratios. We present the effect of mounting type, dc:ac ratio, season, and hour-of-day on these errors for the study site.
Cite
CITATION STYLE
Allen, J. O., & Hobbs, W. B. (2022). The effect of short-term inverter saturation on modeled hourly PV output using minute DC power measurements. Journal of Renewable and Sustainable Energy, 14(6). https://doi.org/10.1063/5.0130265