Abstract
The purpose of this in vitro study was to evaluate the bonding durability of three self-adhesive resin cements to titanium using the Highly Accelerated Life Test (HALT). The following self-adhesive resin cements were used to bond pairs of titanium blocks together according to manufacturers' instructions: RelyX Unicem, Breeze, and Clearfl SA Luting. After storage in water at 37°C for 24 h, bonded specimens (n=15) immersed in 37°C water were subjected to cyclic shear load testing regimes of 20, 30, or 40 kg using a fatigue testing machine. Cyclic loading continued until failure occurred, and the number of cycles taken to reach failure was recorded. The bonding durability of a self-adhesive resin cement to titanium was largely infuenced by the weight of impact load. HALT showed that Clearfl SA Luting, which contained MDP monomer, yielded the highest median bonding lifetime to titanium.
Author supplied keywords
Cite
CITATION STYLE
Lin, J., Shinya, A., Gomi, H., Matinlinna, J. P., & Shinya, A. (2011). In vitro evaluation of the bonding durability of self-adhesive resin cement to titanium using highly accelerated life test. Dental Materials Journal, 30(6), 837–844. https://doi.org/10.4012/dmj.2011-054