Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: Lessons from repeat ablation procedures

76Citations
Citations of this article
68Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims To assess the incidence of late pulmonary vein (PV) reconnection following index PV isolation (PVI) procedure initially achieved with radiofrequency contact-force catheter ablation (CFCA) and second-generation cryoballoon ablation (CB-AdvA). Methods and results A total of 56 consecutive patients (41 male, 73.2%; mean age 60.8 ± 11.8 years) underwent a repeat ablation because of recurrent atrial tachyarrhythmias (ATas) after index PVI achieved with CFCA (30 patients) or CB-AdvA (26 patients). All repeat procedures were performed by the means of CFCA. In the CFCA group, among 119 PVs, 43 (36.1%) showed conduction gaps in 24 patients (1.8 per patient), whereas in the CB-AdvA group among 103 veins, 21 (20.4%) showed a PV reconnection in 18 patients (1.2 per patient) (P = 0.01). The left superior pulmonary vein was less frequently reconnected following CB-AdvA when compared with CFCA (2/25, 8% vs. 11/29, 37.9%; P = 0.01). In the CFCA group, the mean CF per-vein was lower in reconnecting veins when compared with those persistently isolated (10.9 ± 2.7 vs. 18.6 ± 3.1 g; P < 0.001). In the CB-AdvA group, late PV reconnection was associated with warmer nadir temperature (-48.9 ± 5.1 vs. -51.2 ± 4.7°C; P = 0.05) and longer time-to-isolation (71.1 ± 20.2 vs. 50.2 ± 32.9 s; P = 0.03). Conclusion The rate of late PV reconnection is significantly lower following CB-AdvA when compared with CFCA as index procedure. Lower CF values and warmer nadir temperature with longer time to effect were more frequently associated with PV reconnections in the setting of CFCA and CB-AdvA.

Cite

CITATION STYLE

APA

Ciconte, G., Velagić, V., Mugnai, G., Saitoh, Y., Irfan, G., Hunuk, B., … Chierchia, G. B. (2015). Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: Lessons from repeat ablation procedures. Europace, 18(1), 71–77. https://doi.org/10.1093/europace/euv224

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free