Spray coagulation with snare-tip versus argon plasma coagulation: An ex vivo study evaluating tissue effects

4Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background and study aims Argon plasma coagulation (APC) is an effective and safe modality for many gastrointestinal conditions requiring hemostasis and/or ablation. However, it can be quite costly. A potentially more cost-effective alternative is snare-tip spray coagulation (SC). This study aimed to determine whether SC would be a safe and effective alternative to APC using an ex-vivo model. Methods Using two resected porcine stomach, 36 randomized gastric areas were ablated for 2 seconds with either APC at 1.0?L/min 20W (APC20) and 1.4?L/min 40W (APC40) or SC with Effect 2 60W (SC60) and 80W (SC80) from 3 mm. Extent of tissue injury was then analyzed histopathologically. Results The mean coagulation depth was 790 ± 159 µ and 825 ± 467 µ for SC60 (n = 9) and SC80 (n = 8), respectively. This was compared to 539 ± 151 µ for APC20 (n = 8) and 779 ± 267 µ for APC40 (n = 9). Mean difference (MD) in coagulation depth between SC60 and APC40 was 12 µ (95% confidence interval [CI], -191 to 214 µm; P = 0.91) and was 47 µ (95%CI, -162 to 255 µm; P = 0.81) between SC80 and APC40.?There was a greater depth of injury with APC40 (MD, 240 µm; 95%CI, 62 to 418 µ P = 0.04) and with SC60 (MD, 252 µ 95%CI, 141 to 362 µ P = 0.004) when compared to APC20. Mean cross-sectional area of coagulation was 2.39 ± 0.852 mm² for SC60 and 2.54 ± 1.83mm 2; for SC80 compared to 1.22 ± 0.569 mm² for APC20 and 1.99 ± 0.769mm 2; for APC40. Seventy-eight percent reached the muscularis mucosa (MM) and 11% the submucosa in the SC60 group compared to 50% and 38% in SC80 and 56% and 11% in APC40, respectively. Thirty-eight percent of APC20 specimens reached the MM. The muscularis propria was unaffected. Conclusions This small ex-vivo study suggests that SC60 and SC80 may be safe alternatives to APC40 with comparable coagulation depths and area effects.

Cite

CITATION STYLE

APA

Fetz, A., Farnell, D., Irani, S., & Gan, S. I. (2021). Spray coagulation with snare-tip versus argon plasma coagulation: An ex vivo study evaluating tissue effects. Endoscopy International Open, 9(6), E790–E795. https://doi.org/10.1055/a-1373-4162

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free