Rapid exclusion or confirmation of heparin-induced thrombocytopenia: A single-center experience with 1,291 patients

62Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.

Abstract

Background: The current gold-standard for diagnosing heparin-induced thrombocytopenia is the detection of platelet-activating antibodies by means of functional assays which, since they are time consuming and not widely available, are not suited to guiding acute treatment decisions. The objective of our study was to assess the ability of more rapid immunoassays to predict the presence of functionally relevant anti-platelet factor 4/heparin-antibodies. Design and Methods: We analyzed 1,291 of 1,383 (93.4%) patients consecutively evaluated for suspected heparin-induced thrombocytopenia at our institution. Clinical pre-test probability was defined by the 4T-score. Anti-platelet factor 4/heparin-antibodies were measured with three immunoassays (ID-H/PF4-PaGIA, Asserachrom-HPIA, and GTI-PF4) and their functional relevance was assessed by a two-point heparin-induced platelet aggregation test. Performance of the immunoassays was evaluated by receiver operating characteristic analysis. Results: Among 1,291 patients, 96 (7.4%) had a positive heparin-induced platelet aggregation-test: 7 of 859 (0.8%) with a low, 50 of 358 (14.0%) with an intermediate, and 39 of 74 (52.7%) with a high 4T-score. Receiver operating characteristics analysis indicated that best immunoassay thresholds for predicting a positive platelet aggregation test were: Titer of 4 or more (ID-H/PF4-PaGIA), optical density more than 0.943 (Asserachrom-HPIA) and more than 1.367 (GTI-PF4). A 100% negative predictive value was observed at the following thresholds: Titer of 1 or under (ID-H/PF4-PaGIA), optical density less than 0.300 (Asserachrom-HPIA) and less than 0.870 (GTI-PF4). A 100% positive predictive value was reached only by ID-H/PF4-PaGIA, at titers of 32 or over. Positive and negative likelihood ratios were calculated for results between the thresholds with 100% negative or positive predictive value. Conclusions: We show that: i) negative and weak positive results of immunoassays detecting anti-platelet factor 4/heparin-antibodies exclude heparin-induced thrombocytopenia; ii) anti-platelet factor 4/heparin-antibody titers of 32 or over (ID-H/PF4-PaGIA) have a 100% positive predictive value for functionally relevant antibodies; iii) combining the clinical pre-test probability with the likelihood ratio of intermediate immunoassay results allows assessment of post-test probability for heparin-induced thrombocytopenia in individual patients. © 2012 Ferrata Storti Foundation.

Cite

CITATION STYLE

APA

Nellen, V., Sulzer, I., Barizzi, G., Lämmle, B., & Alberio, L. (2012). Rapid exclusion or confirmation of heparin-induced thrombocytopenia: A single-center experience with 1,291 patients. Haematologica, 97(1), 89–97. https://doi.org/10.3324/haematol.2011.048074

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free