Abstract
Monitoring systems are needed to obtain information about particulate matter (PM) concentrations and to make such information accessible to the public. Small, low-cost, optical sensors could be used to improve the spatial and temporal resolution of PM data. The paper presents results of collocated comparison of four low-cost PM sensors and TEOM analyser, conducted from 20-08-2017 to 24-12-2017 in Wrocław, Poland. Plantower PMS7003 and Nova Fitness SDS011 sensors proved to be the best in terms of precision and were linearly correlated with TEOM data. Alphasense OPC-N2 sensors exhibited only moderate precision and linearity. Winsen ZH03A sensors had low repeatability between units and only one copy demonstrated good operation possibilities. All tested sensors had a bias in relation to PM2.5 concentrations obtained from TEOM.
Cite
CITATION STYLE
Badura, M., Batog, P., Drzeniecka-Osiadacz, A., & Modzel, P. (2018). Optical particulate matter sensors in PM2.5 measurements in atmospheric air. In E3S Web of Conferences (Vol. 44). EDP Sciences. https://doi.org/10.1051/e3sconf/20184400006