Abstract
OBJECTIVE: This study aimed to assess the long-term safety and clinical effectiveness of the Xience V everolimus-eluting stent (EES) compared to both Taxus paclitaxel-eluting stent (PES) and Cypher sirolimus-eluting stent (SES) in an unselected patient population. BACKGROUND: There are limited long-term data comparing Xience V EES vs the first-generation Cypher SES. METHODS: This retrospective analysis included 6069 patients treated with Cypher SES, Taxus PES, or Xience V EES from 2003-2009 at our institution. Patients were followed by telephone contact or office visit up to 2 years after the index procedure. RESULTS: Baseline characteristics were generally comparable, with the exception of a significantly higher prevalence of diabetes mellitus, systemic hypertension, history of angioplasty, and coronary bypass surgery among Xience V EES patients. At 2 years, the incidence of major adverse cardiovascular events was 13.3% (Xience V EES) vs 17.8% (Cypher SES) vs 22% (Taxus PES) (P
Author supplied keywords
Cite
CITATION STYLE
Barbash, I. M., Minha, S., Torguson, R., Ben-Dor, I., Badr, S., Loh, J. P., … Waksman, R. (2014). Long-term safety and efficacy of the everolimus-eluting stent compared to first-generation drug-eluting stents in contemporary clinical practice. Journal of Invasive Cardiology, 26(4), 154–160.