Abstract

Purpose: To prospectively evaluate the clinical utility of xSPECT/CT Bone, a new reconstruction algorithm for single photon emission tomography (SPECT), and compare it with standard SPECT/CT reconstruction. Methods: Sequential reporting of SPECT/CT followed by xSPECT/CT images in 200 sequential cases commencing August 2015. Differences between the initial SPECT/CT and the final report (after xSPECT/CT reconstruction) were documented and analysed. 12–18 months after the initial study follow-up, clinical data was sought from a subset of cases in which xSPECT/CT changed the primary diagnosis and imaging correlation undertaken in all patients who subsequently had MRI or CT scans of the same region. Results: A majority of the 200 cases were related to assessment of musculoskeletal complaints. The final (scan) diagnosis was changed after reviewing the xSPECT/CT images in 40 (20%) of cases. The reporting physician (Iain Duncan) assessed that the xSPECT/CT had provided more diagnostic information in 71% of cases. A total of 470 additional lesions were found, equivalent to 2.4 lesions per case. In 33 cases of imaging follow-up there was a high degree of correlation with bone scan findings and xSPECT correlated better than SPECT in regard to detailed findings. In only 15/40 cases of diagnostic change could the outcome be verified and in 12/15 the xSPECT/CT revised diagnosis was confirmed. Conclusions: In this observational evaluation xSPECT/CT Bone reconstruction offers identifiable imaging improvements over standard SPECT/CT reconstruction algorithms. xSPECT/CT Bone provides an improvement in diagnostic confidence and identifies a greater number of lesions.

Cite

CITATION STYLE

APA

Duncan, I., & Ingold, N. (2018). The clinical value of xSPECT/CT Bone versus SPECT/CT. A prospective comparison of 200 scans. European Journal of Hybrid Imaging, 2(1). https://doi.org/10.1186/s41824-017-0024-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free