Abstract
Thresholds for detecting electrical stimulation were measured as a function of (1) body locus, (2) electrode configuration, (3) stimulus waveform, and (4) pulse duration. The results were: (1) the forehead gave slightly, but not reliably, lower thresholds than the abdomen; (2) concentric electrodes gave slightly, but not reliably, lower thresholds than unifocal electrodes; (3) cathodal monophasic (-) pulses and biphasic pulses (+/- and -/+) gave identical thresholds, while anodal monophasic (+) pulses gave higher thresholds; and (4) thresholds decreased as pulse duration increased up to .5 msec, but changed less with longer pulses. © 1982 Psychonomic Society, Inc.
Cite
CITATION STYLE
Girvin, J. P., Marks, L. E., Antunes, J. L., Quest, D. O., O’Keefe, M. D., Ning, P., & Dobelle, W. H. (1982). Electrocutaneous stimulation L The effects of stimulus parameters on absolute threshold. Perception & Psychophysics, 32(6), 524–528. https://doi.org/10.3758/BF03204205