Electrocutaneous stimulation L The effects of stimulus parameters on absolute threshold

19Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Thresholds for detecting electrical stimulation were measured as a function of (1) body locus, (2) electrode configuration, (3) stimulus waveform, and (4) pulse duration. The results were: (1) the forehead gave slightly, but not reliably, lower thresholds than the abdomen; (2) concentric electrodes gave slightly, but not reliably, lower thresholds than unifocal electrodes; (3) cathodal monophasic (-) pulses and biphasic pulses (+/- and -/+) gave identical thresholds, while anodal monophasic (+) pulses gave higher thresholds; and (4) thresholds decreased as pulse duration increased up to .5 msec, but changed less with longer pulses. © 1982 Psychonomic Society, Inc.