Direct injection LC-MS-MS analysis of opiates, methamphetamine, buprenorphine, methadone and their metabolites in oral fluid from substitution therapy patients

26Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed, validated and applied to simultaneous analysis of oral fluid samples for the following 10 analytes: methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), buprenorphine, norbuprenorphine, morphine, codeine, 6-acetylmorphine, 6-acetylcodeine, amphetamine, and methamphetamine. The oral fluid sample was briefly centrifuged and the supernatant was directly injected into the LC-MS-MS system operated under reverse-phase chromatography and electrospray ionization (ESI). Deuterated analogs of the analytes were adopted as the internal standards and found to be effective (except for buprenorphine) to compensate for potential matrix effects. Each analytical run took <10 min. Linearity range (r2 > 0.99) established for buprenorphine and the other nine analytes were 5-100 and 1-100 ng/mL. Intraand interday precision (% CV) ranges for the 10 analytes were 0.87-12.2% and 1.27-12.8%, while the corresponding accuracy (%) ranges were 91.8-113% and 91.9-111%. Limits of detection and quantitation established for these 10 analytes were in the ranges of 0.1-1.0 and 0.25-1.0 ng/mL (5 ng/mL for buprenorphine). The method was successfully applied to the analysis of 62 oral fluid specimens collected from patients participating in methadone and buprenorphine substitution therapy programs. Analytical results of methadone and buprenorphine were compared with data derived from GC-MS analysis and found to be compatible. Overall, the direct injection LC-MS-MS method performed well, permitting rapid analysis of oral fluid samples for simultaneous quantification of methadone, buprenorphine, opiate and amphetamine drug categories without extensive sample preparation steps.

Cite

CITATION STYLE

APA

Liu, H. C., Lee, H. T., Hsu, Y. C., Huang, M. H., Liu, R. H., Chen, T. J., & Lin, D. L. (2015). Direct injection LC-MS-MS analysis of opiates, methamphetamine, buprenorphine, methadone and their metabolites in oral fluid from substitution therapy patients. Journal of Analytical Toxicology, 39(6), 472–480. https://doi.org/10.1093/jat/bkv041

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free