In vivo assessment of optimal b-value range for perfusion-insensitive apparent diffusion coefficient imaging

46Citations
Citations of this article
73Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To assess the optimal b-values range for perfusion-insensitive apparent diffusion coefficient (ADC) imaging of abdominal organs using short-duration DW-MRI acquisitions with currently available ADC estimation methods. Methods: DW-MRI data of 15 subjects were acquired with eight b-values in the range of 5-800 smm2. The reference-standard, a perfusion insensitive, ADC value (ADCIVIM), was computed using an intravoxel incoherent motion (IVIM) model with all acquired diffusion-weighted images. Simulated DW-MRI data was generated using an IVIM model with b-values in the range of 0-1200 smm2. Monoexponential ADC estimates were calculated using: (1) Two-point estimator (ADC2); (2) least squares three-point (ADC3) estimator and; (3) Rician noise model estimator (ADC R). The authors found the optimal b-values for perfusion-insensitive ADC calculations by minimizing the relative root mean square error (RRMS) between the ADCIVIM and the monoexponential ADC values for each estimation method and organ. Results: Low b-value 300 smm2 and high b-value 1200 smm2 minimized the RRMS between the estimated ADC and the reference-standard ADCIVIM to less than 5 using the ADC 3 estimator. By considering only the in vivo DW-MRI data, the combination of low b-value 270 smm2 and high b-value of 800 smm 2 minimized the RRMS between the estimated ADC and the reference-standard ADCIVIM to < 7 using the ADC3 estimator. For all estimators, the RRMS between the estimated ADC and the reference standard ADC correlated strongly with the perfusion-fraction parameter of the IVIM model (r 0.78-0.83, p ≤ 0.003). Conclusions: The perfusion compartment in DW-MRI signal decay correlates strongly with the RRMS in ADC estimates from short-duration DW-MRI. The impact of the perfusion compartment on ADC estimations depends, however, on the choice of b-values and estimation method utilized. Likewise, perfusion-related errors can be reduced to < 7 by carefully selecting the b-values used for ADC calculations and method of estimation. © 2012 American Association of Physicists in Medicine.

Cite

CITATION STYLE

APA

Freiman, M., Voss, S. D., Mulkern, R. V., Perez-Rossello, J. M., Callahan, M. J., & Warfield, S. K. (2012). In vivo assessment of optimal b-value range for perfusion-insensitive apparent diffusion coefficient imaging. Medical Physics, 39(8), 4832–4839. https://doi.org/10.1118/1.4736516

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free