Insufficient endobronchial ultrasound-guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The classification terminology systems for pulmonary cytology specimens have recently emerged. Inadequate samples, classified as "nondiagnostic," raise challenges in determining the threshold of cell numbers and the risk of malignancy (ROM). Methods: The study retrospectively reviewed 248 endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) samples: 46 insufficient samples, 60 low cellularity samples, and 142 adequate samples. Characteristics as cellularity, number of benign and malignant cells, and background features were assessed. Receiver operating characteristic curve analysis was performed to establish cell sufficiency thresholds for the diagnosis. Results: Out of the 248 samples analyzed, 108 were classified as benign, 94 as malignant, and 46 as insufficient. The study found that the cellularity thresholds for diagnosis in cell blocks and cytological samples were ≥50 cells and ≥100 cells, respectively. The thresholds for tumor cell counts were ≥1 − 10 cells for both types of cells, respectively. Considerably, some low cellularity samples were initially classified as insufficient despite meeting the diagnostic thresholds upon revision. The ROM varied across sample categories, with insufficient samples having a ROM of 10.9%, benign samples 15.7%, suspicious samples 92.0%, and malignant samples 100%. Conclusion: Insufficient EBUS-TBNA samples raise challenges in diagnosis and management. This study identified the root cause of insufficient samples, including factors related to humans, diagnostic methods, sampling, and laboratory processing. By understanding the root causes, diagnostic recommendations can be developed to improve the diagnostic process. The findings emphasize the importance of standardized classification and terminology systems for clear communication among healthcare professionals and institutions, ultimately improving patient care and enabling quality assurance measures.

Cite

CITATION STYLE

APA

Vuorisalo, A., Huhtala, H., Paavonen, T., & Kholová, I. (2024). Insufficient endobronchial ultrasound-guided transbronchial needle aspiration specimens. When and why? The analysis of criteria and reasons behind the insufficient specimens. Diagnostic Cytopathology, 52(5), 271–287. https://doi.org/10.1002/dc.25284

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free