Abstract

To compare 5 different Kirschner wire fixation techniques in terms of the failure loads seen as scapholunate (SL) dissociation in a cadaveric, biomechanical study. 10 fresh-frozen, finger-amputated wrists with sectioned SL ligaments from 3 male and 2 female cadavers were tested. The change of SL angle, SL dissociation, and the load to failure of the 5 different Kirschner wire fixation techniques (using 1.4-mm Kirschner wires) were compared using an axial loading testing machine. The techniques were: (1) SL fixation (using one wire), (2) SL fixation (using 2 wires), (3) SL and scaphocapitate (SC) fixation, (4) SL, SC, and capitolunate (CL) fixation, and (5) CL fixation alone. There was no significant difference between SL fixations using one or 2 wires. The force for SL dissociation was significantly greater in the SL-SC fixation than the SL fixation using one wire (p=0.003). The SL-SC-CL fixation was not significantly stronger than the SL-SC fixation. The SL-SC fixation achieved adequate stabilisation of both carpal rows with minimal biological impairment.

Cite

CITATION STYLE

APA

Jakubietz, M. G., Zahn, R., Gruenert, J. G., Waschke, J., Meffert, R. H., & Jakubietz, R. G. (2012). Kirschner wire fixations for scapholunate dissociation: a cadaveric, biomechanical study. Journal of Orthopaedic Surgery (Hong Kong), 20(2), 224–229. https://doi.org/10.1177/230949901202000218

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free