Evaluation of possible corrosion enhancement due to telluric currents: Case study of the Bolivia-Brazil pipeline

10Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

The electric field induced in the Bolivia-Brazil gas pipeline (GASBOL) was calculated by using the distributed source line transmission (DSLT) theory during several space weather events. We used geomagnetic data collected by a fluxgate magnetometer located at São José dos Campos (23.2 S, 45.9 W). The total corrosion rate was calculated by using the Gummow (2002) methodology and was based on the assumption of a 1 cm hole in the coating of the pipeline. The calculations were performed at the ends of pipeline where the largest "out-of-phase" pipe-to-soil potential (PSP) variations were obtained. The variations in PSP during the 17 March 2015 geomagnetic storm have led to the greatest corrosion rate of the analyzed events. All the space weather events evaluated with high terminating impedance may have contributed to increases in the corrosion process. The applied technique can be used to evaluate the corrosion rate due to the high telluric activity associated with the geomagnetic storms at specific locations.

Cite

CITATION STYLE

APA

Fernandes De Moraes, J., Paulino, I., Alves, L. R., & Marcos Denardini, C. (2020). Evaluation of possible corrosion enhancement due to telluric currents: Case study of the Bolivia-Brazil pipeline. Annales Geophysicae, 38(4), 881–888. https://doi.org/10.5194/angeo-38-881-2020

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free