An improved iterative thresholding method to delineate PET volumes using the delineation-averaged signal instead of the enclosed maximum signal

24Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

An improved thresholding method for segmentation of PET volumes is proposed that uses the delineation-averaged activity concentration (AC) within an iterative procedure instead of the enclosed maximum AC. Methods: The average-based iterative thresholding method (avg-ITM) needs the background-corrected relative boundary-reproducing threshold (BRT) curve applied to segment the tumor. On the basis of a previous study, which developed an iterative thresholding method using the maximum AC (max-ITM), the average-based BRT curve was derived from the AC profiles of a sphere model. Numerous phantom scans (using glass spheres, wax spheres, and bihemispheres) under different conditions were obtained to verify and assess the avg-ITM. Clinically, the avg-ITM was tested in 2 patients bearing tumors, and the interobserver and intraobserver variability in the volume segmentation was assessed using 5 tumors analyzed by 5 observers. In the entire study, the max-ITM was also applied to compare the respective results. Results: The phantom measurements verified the averagebased BRT curve and demonstrated that spheric tumors down to a diameter equaling the spatial resolution could be delineated. In contrast to the max-ITM, the avg-ITM yielded reliable volumes (within the 95% confidence intervals) for standardized uptake values and signal-to-background ratios larger than 3. The volumes derived using the max-ITM were significantly underestimated for object sizes with diameters considerably larger than the spatial resolution. Phantom measurements using bihemispheres with decreasing AC ratios demonstrated that the avg-ITM was robust down to an AC ratio of 0.5 and, therefore, is less prone to nonuniformity than the max-ITM, which was corroborated by real tumor imaging. The observer-related variability was small (mean absolute relative SD < 4%). Conclusion: Compared with the max-ITM, the avg-ITM improves the segmentation results for large objects and is less sensitive against image noise and nonuniformity. A clinical comparison study is warranted to assess the benefits of the avg-ITM method compared with other segmentation methods.

Cite

CITATION STYLE

APA

Jentzen, W. (2015). An improved iterative thresholding method to delineate PET volumes using the delineation-averaged signal instead of the enclosed maximum signal. Journal of Nuclear Medicine Technology, 43(1), 28–35. https://doi.org/10.2967/jnmt.114.152678

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free