The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine

22Citations
Citations of this article
45Readers
Mendeley users who have this article in their library.

Abstract

To evaluate the feasibility of a minimally invasive technique using a titanium expandable device to achieve anatomical restoration of vertebral compression fractures (VCF) of the thoracolumbar spine. Methods: This prospective study included 27 patients diagnosed with VCF (Magerl classification A.1.2, A.1.3, and A.3.1) of the thoracolumbar spine treated with percutaneous cement augmentation using the SpineJack® device. The study was conducted in Valladolid University Hospital, Valladolid, Spain from January to December 2012, with a minimum one-year follow up. Preoperative evaluation included visual analogue scale (VAS) for pain, and radiological assessment of the VCF using 3-dimensional computed tomography (3D-CT) scans for measurements of vertebral heights and angles. The patients were followed at 3, 6, and 12 months with clinical VAS and radiological assessments. Results: The procedure was performed in 27 patients with a mean age of 55.9 ± 17.3 years, 55.6% females. All patients underwent surgery within 6 weeks from time of injury. No procedure related complications occurred. Pain measured by VAS score decreased from 7.0 preoperatively to 3.2 within 24 hours, and remained 2.2 at 3 months, 2.1 at 6 months, and 1.5 at 12-months follow-up (p<0.05). Mean height restorations for the anterior was 3.56 mm, central was 2.49, and posterior vertebral was 1.28 mm, and maintained at 12-months follow-up (p=0.001). Conclusion: This new percutaneous technique for VCF has shown good clinical results in pain control and the possibility to reduce both vertebral kyphosis angles and fractured endplates seen in 3D-CT scans assessment method. Further studies are needed to confirm those results on larger cohorts with long-term follow up.

Cite

CITATION STYLE

APA

Baeesa, S. S., Krueger, A., Aragón, F. A., & Noriega, D. C. (2015). The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine. Saudi Medical Journal, 36(1), 52–60. https://doi.org/10.15537/smj.2015.1.9463

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free