Can radiation dose in mammography be further reduced by increasing the image quality?

  • O'Leary D
  • Rainford L
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction Efforts to reduce radiation dose should be linked to and limited by image quality and the radiation dose should only be lowered to levels compatible with image quality for adequate diagnosis; this is optimisation of mammography. Despite this link between image quality and mean glandular dose (MGD), the MGD is proposed only with regard to compression level achieved or population percentile, not image quality required/achieved. Methods A study of symptomatic breast units geographically spread over Ireland collected image quality and radiation dose data. The quantitative and qualitative data were analysed using mathematical modelling and SPSS statistics including ANOVA. High image quality was matched to lowest achievable radiation doses; inadequate images were discarded from the dataset for recommendations of achievable MGD. Results MGDs received by perfect images are significantly lower than the radiation doses received by inadequate images. This is seen in both digital images and film-screen images and for both mammographic projections: digital craniocaudal, F(3,978) = 2.841, P = 0.37; digital mediolateral oblique, F(3,977) = 4.896, P = 0.002; analogue craniocaudal, F(3,785) = 7.993, P <0.001; analogue mediolateral oblique, F(3,783) = 7.961, P <0.001). The mean MGD in mGy required to produce a perfect image in each of the categories: digital craniocaudal, 1.23 mGy; digital mediolateral oblique, 1.28 mGy; analogue craniocaudal, 2.10 mGy; analogue mediolateral oblique, 2.25 mGy. Conclusion The publication of average glandular dose must be linked to image quality achieved and the percentage of inadequate images in the data collection must be explicit. The radiation doses can be lowered further in digital imaging by greater training of radiographers to consistently achieve perfect mammography images.

Cite

CITATION STYLE

APA

O’Leary, D., & Rainford, L. (2011). Can radiation dose in mammography be further reduced by increasing the image quality? Breast Cancer Research, 13(S1). https://doi.org/10.1186/bcr2973

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free