Standard automated perimetry using size III and size v stimuli in advanced stage glaucoma: An observational cross-sectional comparative study

2Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

Objectives In this study, we sought to evaluate the extent of further visual field that could be assessed when using stimulus size V in standard automated perimetry compared with size III in advanced stage glaucoma and whether cut-off values could be determined for when to switch from size III to size V. Design Prospective cross-sectional study. Setting Single-centre outpatient eye clinic in India (New Delhi). Participants Advanced stage glaucoma defined as stages 3-4. Intervention Central static perimetry with Octopus 900 G programme (size III stimulus dynamic strategy) and low vision central programme (size V stimulus dynamic strategy). Primary and secondary outcome measures Visual field assessment for right and left eyes with both sizes III and V were undertaken within one clinic visit. Results We recruited 126 patients (170 eyes). Mean patient age at assessment was 55.86 years (SD 15.15). Means (SD) for size III versus size V, respectively, were 6.94 dB (5.58) and 12.98 dB (7.77) for mean sensitivity, 20.02 dB (5.67) and 19.22 dB (7.74) for mean deviation, 5.89 dB (2.29) and 7.69 dB (2.78) for standard loss variance and 3.32 min (1.07) and 6.40 min (1.43) for test duration. All except mean deviation were significantly different between size III and V tests. Conclusion Useful visual field information was obtained with size V stimuli which allowed continued monitoring of these patients that was not possible with size III. Increased test duration, standard loss variance and mean sensitivity were found with size V, as expected, given that more visual responses were obtained with the increased target size. A switch from size III to V may be considered when mean sensitivity reaches 10 dB and/or mean deviation reaches 18 dB.

Cite

CITATION STYLE

APA

Sood, D., Czanner, G., Somerville, T., Sood, I., & Rowe, F. J. (2021). Standard automated perimetry using size III and size v stimuli in advanced stage glaucoma: An observational cross-sectional comparative study. BMJ Open, 11(9). https://doi.org/10.1136/bmjopen-2020-046124

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free