A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients

290Citations
Citations of this article
149Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In three clinical centres, we compared a new method for measuring cardiac output with conventional thermodilution. The new method computes beat-to-beat cardiac output from radial artery pressure by simulating a three-element model of aortic input impedance, and includes non-linear aortic mechanical properties and a self-adapting systemic vascular resistance. We compared cardiac output by continuous model simulation (MF) with thermodilution cardiac output (TD) in 54 patients (18 female, 36 male) undergoing coronary artery bypass surgery. We made three or four conventional thermodilution estimates spread equally over the ventilatory cycle. In 490 series of measurements, thermodilution cardiac output ranged from 2.1 to 9.3, mean 5.0 litre min-1. MF differed +0.32 (1.0) litre min-1 on average with limits of agreement of -1.68 and +2.32 litre min-1. Differences decreased when the first series of measurements in a patient was used to calibrate the model. In 436 remaining series, the mean difference became -0.13 (0.47) litre min-1 with limits of agreement of -1.05 and +0.79 litre min-1. When consecutive measurements were made, the change was greater than 0.5 litre min-1, on 204 occasions. The direction of change was the same with both methods in 199. The difference between the methods remained near zero during surgery suggesting that a single calibration per patient was adequate. Aortic model simulation with radial artery pressure as input reliably monitors changes in cardiac output in cardiac surgery patients. Before calibration, the model cannot replace thermodilution, but after calibration the model method can quantitatively replace further thermodilution estimates.

Cite

CITATION STYLE

APA

Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001). A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. British Journal of Anaesthesia, 87(2), 212–222. https://doi.org/10.1093/bja/87.2.212

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free