Early calibration problems detected in TOMS Earth-Probe aeorosol signal

26Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

TOMS (version 8) ozone and aerosol data are analyzed in order to extract characteristic temporal patterns on a near global scale. A clear annual cycle of the global average for the ozone is apparent in the measured intervals (Nimbus-7: 1978-1993, Earth-Probe: 1996-2005), however a similar initial periodicity disappears for the aerosol index in the Earth-Probe records. A detailed spectral analysis revealed significant asymmetries in the Nimbus-7 aerosol signal for the two hemispheres, which is not present in Earth-Probe data. The available record from the Ozone Monitoring Instrument (one and a half years) shows a return to the seasonal variability seen by Nimbus-7 in both hemispheres. This suggests that calibration difficulties of the Earth-Probe instrument started earlier than mid 2000, when it became apparent from many indications. Copyright 2007 by the American Geophysical Union.

Cite

CITATION STYLE

APA

Kiss, P., Jánosi, I. M., & Torres, O. (2007). Early calibration problems detected in TOMS Earth-Probe aeorosol signal. Geophysical Research Letters, 34(7). https://doi.org/10.1029/2006GL028108