Alternative approach for right ventricular failure after left ventricular assist device placement in animal model

4Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Right ventricular failure after left ventricular assist device (LVAD) implantation is associated with high mortality. This study was designed to evaluate the effectiveness of an atrial septostomy with a membrane oxygenator incorporated in an LVAD as a novel approach for right ventricular failure after LVAD implantation. METHODS: The outflow and inflow cannulae were placed in the carotid artery and left ventricular apex, respectively. A centrifugal pump and an oxygenator were sequentially placed between the inflow and outflow cannulae in seven anesthetized goats. While right ventricular failure was induced by pulmonary artery banding, a balloon atrial septostomy was performed using a 19-mm balloon catheter under echocardiographic guidance. We investigated the effects of the interatrial shunt on LVAD flow and haemodynamics. RESULTS: Development of right ventricular failure decreased LVAD flow (2.7 ± 0.6-0.9 ± 0.6 l/min), causing a state of shock [mean arterial pressure (MAP) of 41 ± 12 mmHg]. Following a balloon atrial septostomy, LVAD flow and MAP were significantly improved to 2.7 ± 0.4 l/min (P < 0.001) and 53 ± 18 mmHg (P = 0.006), respectively, while right atrial pressure decreased from 18 ± 5 to 15 ± 5 mmHg (P = 0.001). Furthermore, arterial blood oxygenation was maintained by the membrane oxygenator incorporated in the LVAD. CONCLUSIONS: In the present model of right ventricular failure after LVAD implantation, LVAD flow was significantly increased and haemodynamics improved without compromising systemic oxygenation by the use of an interatrial shunt and a membrane oxygenator incorporated in the LVAD. Our results indicate that this novel approach may be less invasive for a right ventricular failure after LVAD implantation.

Cite

CITATION STYLE

APA

Saito, T., Toda, K., Takewa, Y., Tsukiya, T., Mizuno, T., Taenaka, Y., & Tatsumi, E. (2015). Alternative approach for right ventricular failure after left ventricular assist device placement in animal model. European Journal of Cardio-Thoracic Surgery, 48(1), 98–103. https://doi.org/10.1093/ejcts/ezu364

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free