Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system

49Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

Abstract

A continuous closed-loop insulin delivery system using subcutaneous insulin delivery was evaluated in eight diabetic canines. Continuous glucose profiles were obtained by extrapolation of blood glucose measurements. Insulin delivery rate was calculated, using a model of β-cell insulin secretion, and delivered with a Medtronic MiniMed subcutaneous infusion pump. The model acts like a classic proportional-integral-derivative controller, delivering insulin in proportion to glucose above target, history of past glucose values, and glucose rate of change. For each dog, a proportional gain was set relative to the open-loop total daily dose (TDD) of insulin. Additional gains based on 0.5 x TDD and 1.5 x TDD were also evaluated (gain dose response). Control was initiated 4 h before the meal with a target of 6.7 mmol/l. At the time of the meal, glucose was similar for all three gains (6.0 ± 0.3, 5.2 ± 0.3, and 4.9 ± 0.5 mmol/l for 0.5 x TDD, TDD, and 1.5 x TDD, respectively; P > 0.05) with near-target values restored at the end of experiments (8.2 ± 0.9, 6.0 ± 0.6, and 6.0 ± 0.5, respectively). The peak postprandial glucose level decreased significantly with increasing gain (12.1 ± 0.6, 9.6 ± 1.0, and 8.5 ± 0.6 mmol/l, respectively; P < 0.05). The data demonstrate that closed-loop insulin delivery using the subcutaneous site can provide stable glycemic control within a range of gain. Integration of glucose-sensing and insulin delivery technologies can potentially lead to a fully ambulatory closed-loop insulin delivery system or "artificial pancreas." Such a system may achieve glucose and insulin profiles near those observed in individuals with normal glucose tolerance while at the same time decreasing the incidence of hypoglycemia and minimizing the complications of diabetes. © 2006 by the American Diabetes Association.

Cite

CITATION STYLE

APA

Panteleon, A. E., Loutseiko, M., Steil, G. M., & Rebrin, K. (2006). Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system. Diabetes, 55(7), 1995–2000. https://doi.org/10.2337/db05-1346

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free