Abstract
Background: Remote magnetic navigation (RMN) has been reported as a feasible and safe mapping and ablation system for treatment of ventricular arrhythmias (VAs). However, the reported success rates have been limited with the 4- and 8-mm catheter tips. Objective: This study sought to report the results in a large series of consecutive patients undergoing radiofrequency (RF) catheter ablation of VAs using the RMN with the 3.5-mm magnetic open-irrigated-tip catheter (OIC). Methods: A total of 110 consecutive patients with a clinical history of left VA were included in the study. In all cases, an OIC was utilized for mapping and ablation. When ablation with the RMN catheters failed, a manual OIC was used to eliminate the VA. Postablation pacing maneuvers and isoproterenol were used to verify the inducibility of the VAs. Outcomes were compared with those of a group of 92 consecutive patients undergoing manual ablation by the same operator. Results: Mapping and ablation with the magnetic OIC were performed in all 110 patients with VA. Ischemic cardiomyopathy was present in 33 (30%), nonischemic in 14 (13%), and in 63 (57%) patients no structural heart disease was present. Endocardial mapping was performed in all patients, whereas both endocardial and epicardial mapping were performed in 36 (33%) patients. Compared with manual ablation, RMN was associated with a longer procedural time (2.9 ± 1.2 hours vs. 3.3 ± 1.1 hours, P = 0.004) and RF time (24 ± 12 minutes vs. 33 ± 18 minutes, P = 0.005), whereas fluoroscopic time was significantly shorter (35 ± 22 minutes vs. 26 ± 14 minutes, P = 0.033). During the procedures, crossover to manual ablation was required in 15 patients (14%). At 11.7 ± 2.1 months of follow-up in the study group and 18.7 ± 3.7 months in the manual ablation group, 85% and 86% (P = 0.817) of patients, respectively, were free of VA. Conclusion: This large series of consecutive patients demonstrates that OIC ablation using RMN is effective for the treatment of left VAs. © 2010 Heart Rhythm Society.
Author supplied keywords
Cite
CITATION STYLE
Di Biase, L., Santangeli, P., Astudillo, V., Conti, S., Mohanty, P., Mohanty, S., … Natale, A. (2010). Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the Remote Magnetic Navigation System and the 3.5-mm open irrigated magnetic catheter: Results from a large single-center case-control series. Heart Rhythm, 7(8), 1029–1035. https://doi.org/10.1016/j.hrthm.2010.04.036
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.