Thermal Performance of Composite Roof Structures with Insulating Layers in Non Conditioned Buildings for Hot Dry Climate

  • Rawat M
  • et al.
N/ACitations
Citations of this article
4Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The roof configurations with an insulating layer and their impact on hourly floating temperature analyzed in a hot-dry climate context. A predefined computer program using a modified Fourier admittance method utilized as the primary research. The thermal performance of ten composite roof structures evaluated to obtain optimal roof structure for hot-dry climate, Jodhpur. Nine composite roof structures with an insulation layer and one without insulation layer as the base case were analyzed for the summer months (April-September). The utilization of roof thermal insulation showed a significant influence on the overall thermal performance of roofs. It also revealed that minimum temperature variation found about 8.8 0C for the composite roof structure of Reinforced Cement Concrete (RCC) with foam concrete insulation (i.e., RF-5) with thicknesses 150 mm and 140 mm respectively. The analysis assessed that composite roof structure with an insulating layer is a useful technique to reduced indoor temperature in non-conditioned buildings of hot-dry climate.

Cite

CITATION STYLE

APA

Rawat, Mr. M., & Singh, Dr. R. N. (2020). Thermal Performance of Composite Roof Structures with Insulating Layers in Non Conditioned Buildings for Hot Dry Climate. International Journal of Recent Technology and Engineering (IJRTE), 9(3), 122–127. https://doi.org/10.35940/ijrte.c4272.099320

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free