Dynamic Analysis of Absorption Column

  • Yousif Ghadhban M
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

The absorption column is one of the essential separation processes in industrial operation, so the need arises to control absorption column by process simulation and also to analyze system by method called frequency response using MATLAB8. This work dealt with gas-liquid (air-water) absorption packed column which is analyzed by bode plot and frequency response to determine the stability of the system with or without Proportional Controller (P), Proportional Integral Controller (PI) or Proportional Integral Derivatives Controller (PID).The frequency response gives the transient response information, by defining such frequency response quantities as gain margin and phase margin. This work presents dynamic analysis of absorption column which is single input/single output (SISO) using feedback control (P, PI and PID) with the parameters of Cohen-Coon, Ziegler Nichols and Internal Model control and compares between them.

Cite

CITATION STYLE

APA

Yousif Ghadhban, M. (2016). Dynamic Analysis of Absorption Column. University of Thi-Qar Journal for Engineering Sciences, 7(2), 104–119. https://doi.org/10.31663/utjes.v7i2.63

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free