Preliminary research on eddy current bobbin quantitative test for heat exchange tube in nuclear power plant

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

For quantitative defects detection research on heat transfer tube in nuclear power plants (NPP), two parts of work are carried out based on the crack as the main research objects. (1) Production optimization of calibration tube. Firstly, ASME, RSEM and homemade crack calibration tubes are applied to quantitatively analyze the defects depth on other designed crack test tubes, and then the judgment with quantitative results under crack calibration tube with more accuracy is given. Base on that, weight analysis of influence factors for crack depth quantitative test such as crack orientation, length, volume and so on can be undertaken, which will optimize manufacture technology of calibration tubes. (2) Quantitative optimization of crack depth. Neural network model with multi-calibration curve adopted to optimize natural crack test depth generated in in-service tubes shows preliminary ability to improve quantitative accuracy.

Cite

CITATION STYLE

APA

Qi, P., Shao, W., & Liao, S. (2016). Preliminary research on eddy current bobbin quantitative test for heat exchange tube in nuclear power plant. In AIP Conference Proceedings (Vol. 1706). American Institute of Physics Inc. https://doi.org/10.1063/1.4940551