AepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anaesthesia

33Citations
Citations of this article
71Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Previously, we showed a significant difference in the measurements of hypnotic depth by the bispectral index (BIS) and auditory-evoked potentials (AEPs) using the A-line autoregressive index during xenon anaesthesia. In the present study, we evaluate the alternative AEP-based auditory-evoked potential index (aepEX) for the measurement of hypnotic depth in patients undergoing general anaesthesia with xenon. Methods: Forty-two patients undergoing elective abdominal surgery were enrolled in this controlled, double-blinded, randomized, clinical study. Patients were randomized to receive either xenon (n=21) or sevoflurane anaesthesia (n=21). During anaesthesia, BIS values were recorded simultaneously with the aepEX monitoring. The anaesthetist performing the anaesthesia was blinded to the hypnotic depth monitors. After surgery, the incidence of recalls and awareness was evaluated. Results: Patients characteristics such as gender, age, and weight did not differ between the groups. The aepEX and BIS values behaved similarly during anaesthesia. The comparison of aepEX values during xenon and sevoflurane anaesthesia revealed significantly lower aepEX values in the xenon group after 25 min [xenon: 32.9 (4.8) vs sevoflurane: 39.3 (9.0); P=0.008] and after 35 min [xenon: 31.4 (6.6) vs sevoflurane: 37.0 (6.8); P=0.012]. During anaesthesia, aepEX values correlated with the clinical evaluation of depth of anaesthesia (e.g. >20 changes of the baseline arterial pressure or heart rate, spontaneous breathing and/or intolerance of mechanical ventilation, coughing, abdominal pressing, sweating, eye tearing). ConclusionsWe found the aepEX monitor to provide index in the range of adequate depth of xenon anaesthesia, when combined with remifentanil infusion in intubated patients undergoing elective abdominal surgery. © 2011 The Author Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved.

Cite

CITATION STYLE

APA

Stoppe, C., Peters, D., Fahlenkamp, A. V., Cremer, J., Rex, S., Schälte, G., … Coburn, M. (2012). AepEX monitor for the measurement of hypnotic depth in patients undergoing balanced xenon anaesthesia. British Journal of Anaesthesia, 108(1), 80–88. https://doi.org/10.1093/bja/aer393

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free