Erratum: Effect of thermoelectric placement on the commercial waterblock to the liquid cooling system performance (J. Phys.: Conf. Ser. (2021) 1763 (012039) DOI: 10.1088/1742-6596/1763/1/012039)

0Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Page 1: In the Introduction section line 13-15, the following text appears: “Azimi et al. [8] use the water is cooled by passing through a block which is on contact with the cold side of a thermoelectric in the liquid cooling garment, showed that temperature difference versus the number of fins and the block dimensions has increasing behavior.” This should read: “Azimi et al. [7] use the water is cooled by passing through a block which is on contact with the cold side of a thermoelectric in the liquid cooling garment, showed that temperature difference versus the number of fins and the block dimensions has increasing behavior. This should read: “Azimi et al. [7] use the water is cooled by passing through a block which is on contact with the cold side of a thermoelectric in the liquid cooling garment, showed that temperature difference versus the number of fins and the block dimensions has increasing behavior.” Page 3: In the sub section 2.2, the following text appears: “The performance of thermoelectric modules known from the amount of heat that is pumped by the Peltier effect, heat moves from the hot side to the cold side because of the thermal conductivity of the thermoelectric material, and a portion of the total Joule heating effect generated by the electric current to thermal resistance. From the energy equilibrium is obtained:” This should read: "The performance of thermoelectric modules known from the amount of heat that is pumped by the Peltier effect, heat moves from the hot side to the cold side because of the thermal conductivity of the thermoelectric material, and a portion of the total Joule heating effect generated by the electric current to thermal resistance. From the energy equilibrium is obtained [10]:” Page 4: In the Figure 3, the following figure appears: (Figure Presented). This should be appeared: (Figure Presented) Page 6: In in the second line of the first paragraph, the following text appears: “Observations through CFD were compared with experimental data to validate the simulation results. The simulation uses standard k- model turbulence, and boundary condition parameters are referred to the observed data.” This should read: "Observations through CFD were compared with experimental data to validate the simulation results. The simulation uses standard k-e model turbulence, and boundary condition parameters are referred to the observed data.

Cite

CITATION STYLE

APA

Kennedy, Anwar, K., Muis, A., Basri, B., & Ilhamsyah, M. (2021, February 2). Erratum: Effect of thermoelectric placement on the commercial waterblock to the liquid cooling system performance (J. Phys.: Conf. Ser. (2021) 1763 (012039) DOI: 10.1088/1742-6596/1763/1/012039). Journal of Physics: Conference Series. IOP Publishing Ltd. https://doi.org/10.1088/1742-6596/1763/1/012095

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free