SIMS depth profiling of implanted helium in Al-Mn alloy using CsHe+ molecular ion detection

3Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The use of Cs+ primary ions in conjunction with the detection of CsHe+ molecular ions is proposed for the analysis of helium in metals by secondary ion mass spectrometry (SIMS). Concentration depth profiles of helium implanted at 100keV in Al60Mn40 alloy have been measured. Helium concentrations down to about 100 ppm were measured at moderately low sputtering rate of 0·5nm/sec. The experimentally determined implantation profile of helium is compared with the theoretical profile obtained using the Monte Carlo Code TRIM. © 1993 Indian Academy of Sciences.

Cite

CITATION STYLE

APA

Tyagi, A. K., Nair, K. G. M., & Krishan, K. (1993). SIMS depth profiling of implanted helium in Al-Mn alloy using CsHe+ molecular ion detection. Bulletin of Materials Science, 16(1), 45–49. https://doi.org/10.1007/BF02745306

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free