Reliability and validity of the Actiwatch and Clouclip for measuring illumination in real-world conditions

23Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare real-world measures of illumination obtained with the Actiwatch-2 and Clouclip-M2 with ‘gold standard’ photometry measures and to evaluate the ability of Actiwatch-2 to correctly identify photometer-defined conditions: scotopic (≤0.01 lux), mesopic (0.02–3 lux), indoor photopic (>3–1,000 lux) and outdoor photopic (>1,000 lux); and Clouclip to correctly identify photometer-defined conditions within its operating range (>1 lux). Inter-device reliability of Clouclip for illumination and viewing distance measures was also investigated. Methods: A Hagner-S2 photometer was used as reference. Measures of illumination were obtained from a range of real-world conditions. To investigate inter-device reliability, five Clouclips were simultaneously exposed to varied light conditions and object distances. Results: Strong correlations existed between illumination measured with the photometer and both Actiwatch-2 (ρ = 0.99, p < 0.0001) and Clouclip (ρ = 0.99, p < 0.0001). However, both devices underestimated illumination compared to the photometer; disparity increased with increasing illumination and was greater for Actiwatch-2 than Clouclip measures. Actiwatch-2 successfully categorised illumination level (scotopic, mesopic, indoor and outdoor photopic) in 71.2% of cases. Clouclip successfully categorised illumination levels as scotopic/mesopic (≤3 lux) and indoor and outdoor photopic in 100% of cases. Mean differences and limits of agreement (LOA) were 430.92 ± 1,828.74 and 79.35 ± 407.33 lux, between the photometer and Actiwatch-2 and photometer and Clouclip, respectively. The Intra-class Correlation Coefficients for illumination and viewing distance measured with five Clouclips were 0.85 and 0.96, respectively. Conclusion: These data illustrate that different Clouclip devices produce comparable measures of viewing distance and illumination in real-world settings. Both Actiwatch-2 and Clouclip underestimate illumination in the field compared to gold standard photometer measures. The disparity increases at higher levels of illumination and the discrepancy was greater for Actiwatch-2 measures. For researchers interested in categorising light exposure, Clouclip classifies illumination levels >2 lux more accurately than Actiwatch-2 but cannot discriminate between scotopic and low mesopic light.

Cite

CITATION STYLE

APA

Howell, C. M., McCullough, S. J., Doyle, L., Murphy, M. H., & Saunders, K. J. (2021). Reliability and validity of the Actiwatch and Clouclip for measuring illumination in real-world conditions. Ophthalmic and Physiological Optics, 41(5), 1048–1059. https://doi.org/10.1111/opo.12860

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free