The impact of the use of a CPRMeter monitor on quality of chest compressions: A prospective randomised trial, cross-simulation

16Citations
Citations of this article
72Readers
Mendeley users who have this article in their library.

Abstract

Background: Drowning is a common issue at many pools and beaches, and in seas all over the world. Lifeguards often act as bystanders, and therefore adequate training in high-quality cardiopulmonary resuscitation (CPR) and use of adequate equipment by lifeguards is essential. Aim: The aim of this study was to evaluate the impact of the recently introduced CPRMeter (Laerdal, Stavanger, Norway) on quality of CPR, if used by moderately experienced CPR providers. In particular, we tested the hypothesis that using the CPRMeter improves quality of chest compression by lifeguards compared to standard non-feedback CPR. Methods: The study was designed as prospective, randomised, cross-over manikin trial. Fifty lifeguards of the Volunteer Water Rescue Service (WOPR), a Polish nationwide association specialised in water rescue, participated in this study. Participants were randomly assigned 1:1 to one of two groups: a feedback group and a non-feedback group. Participants swim a distance of 25 m in the pool, and then they were asked to haul a manikin for the second 25 m, simulating rescuing a drowning victim. Once participants finished the second 25-m distance, participants were asked to initiate 2-min basic life support according to the randomisation. Results: The median quality of CPR score for the 2-min CPR session without feedback was 69 (33–77) compared to 84 (55–93) in the feedback group (p < 0.001). Compression score, mean depth, rate of adequate chest compressions/min, and overall mean rate during the CPR session improved significantly in the feedback group, compared to the non-feedback group. Conclusions: Using the visual real-time feedback device significantly improved quality of CPR in our relatively unexperienced CPR providers. Better quality of bystander CPR is essential for clinical outcomes, and therefore feedback devices should be considered. Further clinical studies are needed to assess the effect of real-time visual devices, especially in bystander-CPR.

Cite

CITATION STYLE

APA

Iskrzycki, L., Smereka, J., Rodriguez-Nunez, A., Furelos, R. B., Gomez, C. A., Kaminska, H., … Ladny, J. R. (2017, December 15). The impact of the use of a CPRMeter monitor on quality of chest compressions: A prospective randomised trial, cross-simulation. Kardiologia Polska. Medycyna Praktyczna Cholerzyn. https://doi.org/10.5603/KP.A2017.0255

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free