Abstract
By an extension of the reciprocity principle for the absolute measurement of sound, it is demonstrated that a calibration may be obtained on a single transducer without the aid of auxiliary transducers. Measurements using the technique are described and shown to give satisfactory agreement with conventional calibrations.
Cite
CITATION STYLE
APA
Carstensen, E. L. (1947). Self-Reciprocity Calibration of Electroacoustic Transducers. The Journal of the Acoustical Society of America, 19(6), 961–965. https://doi.org/10.1121/1.1916647