Abstract
Background: Cranial cruciate ligament (CCL) rupture is the most common orthopedic pathology in dog and in men. In human, optical computer-assisted technique is considered as a repeatable and reliable method for the biomechanical assessment of joint kinematics and laxity in case of CCL surgery. Aim: To evaluate the repeatability and reliability afforded by clinical tests in terms of laxity measured by means of a computer-assisted tracking system in two canine CCL conditions: CCL-Intact, CCL-Deficient. Methods: Fourteen fresh frozen canine stifles were passively subjected to Internal/External (IE) rotation at 120° of flexion and Cranial drawer test (CC). To quantify the repeatability and the reliability, intra-class correlation coefficient (ICC) and the mean percent error were evaluated (Δ r %). Results: The study showed a very good intra-class correlation, before and after CCL resection for kinematics tests. It was found a minimum ICC = 0.73 during the IE rotation in CCL-Intact and a maximum value of ICC = 0.97 for the CC displacement in CC-Deficient. IE rotation with CCL-Intact is the condition with the greatest Δ r % = 14%, while the lowest Δ r % = 6% was obtained for CC displacement in CCL-Deficient. Conclusion: The presented work underlined the possibility of using a computer-assisted method also for biomechanical studies concerning stifle kinematics and laxity.
Author supplied keywords
Cite
CITATION STYLE
Signorelli, C., Cinti, F., Zaffagnini, S., Pisoni, L., & Lopomo, N. F. (2020). Validation of an optical, computer-assisted technique for intraoperative tracking of 3-dimensional canine stifle joint motion. Open Veterinary Journal, 10(1), 86–93. https://doi.org/10.4314/ovj.v10i1.14
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.