Determination of decimal reduction time (D-value) of chemical agents used in hospital disinfection

3Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Prior to selecting disinfectant for low, intermediate and high (sterilizing) levels, the decimal reduction time, D-value, for the most common or persistent bacteria identified on a medical device or at a health care facility should be determined. The D-value was determined by inoculating 100 mL of disinfecting solution with 1 mL of a bacterial suspension. At regular intervals, 1 mL aliquots of this mixture were transferred to 8 mL of growth media containing a neutralizing agent, and incubated at optimal conditions for the microorganism. B. stearothermophilus and E. coli were the most resistant bacteria for the disinfecting and sterilizing procedures.

Cite

CITATION STYLE

APA

Mazzola, P. G., Da Silva Martins, A. M., & Vessoni Penna, T. C. (2003). Determination of decimal reduction time (D-value) of chemical agents used in hospital disinfection. Brazilian Journal of Microbiology, 34(SUPPL. 1), 33–34. https://doi.org/10.1590/S1517-83822003000500011