Near-Infrared Spectroscopic Measurement of Glucose in a Protein Matrix

81Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A method is described for measuring clinically relevant levels of glucose in a protein matrix by near-infrared (near-IR) absorption spectroscopy. Results from an initial screening of major blood constituents identify protein as a major potential interference to the near-IR measurement of glucose in blood. The interference by protein is caused by relatively high concentrations coupled with strong near-IR absorption bands between 5000 and 4000 cm-1 (2.0-2.5μm). Calibration models based on a simple univariate calibration procedure are not capable of providing accurate glucose concentrations from an independent set of prediction spectra. By use of the multivariate technique of partial least squares (PLS) regression, glucose concentrations can be determined with a 0.35 mM (6.3 mg/dL) standard error of prediction. The spectral range for this calibration model extends from 4600 to 4200 cm-1, and the optimum number of PLS factors is 14. In addition, calibration models based on a combination of digital Fourier filtering and PLS regression have been constructed and evaluated. Superior calibration models are obtained by using a preprocessing digital filtering step to remove spectral features not associated with glucose. The best overall calibration model was obtained by using a Gaussian-shaped Fourier filter defined by a mean position of 0.03f and standard deviation of 0.007f coupled with a 12-factor PLS regression computed over the spectral range from 4600 to 4200 cm-1. This model provided a standard error of prediction of 0.24 mM (4.3 mg/dL) for an independent set of prediction spectra. The effects of spectral range and number of PLS factors are considered for calibration models based on both PLS alone and PLS coupled with Fourier filtering. For both calibration methods, the 4400-cm-1 (2.27-μm) glucose absorption band appears to provide most of the reliable glucose concentration information. © 1993, American Chemical Society. All rights reserved.

Cite

CITATION STYLE

APA

Marquardt, L. A., Arnold, M. A., & Small, G. W. (1993). Near-Infrared Spectroscopic Measurement of Glucose in a Protein Matrix. Analytical Chemistry, 65(22), 3271–3278. https://doi.org/10.1021/ac00070a018

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free