Abstract
A biotrickling filter (BTF) was designed for removal of sulfite (SO2-3), sulfate (SO2-4), and hydrosulfite (HSO-3) produced from flue gas adsorbent during dual-alkali flue gas desulfurization. With an SO2-3 concentration of 0.89 g-S/(L packing), BTF could completely remove SO2-3 within 3 h with an elimination capacity (EC) of 296 g-S/(m3h). With an SO2-3 concentration of 0.60 g-S/(L packing), the removal efficiency (RE) of SO2-4 reached 90.3% at 5.25 h and 95% at 24 h. With an HSO-3 concentration of 0.74 g-S/(L packing), HSO-3 could not be detected in the trickling liquid at 2 h with an EC of 370 g-S/ (m3h). The difference in desulfurization performance of the BTF was minor when sodium lactate and sodium acetate were used as carbon sources. Acetate was more superior when taking both the carbon/sulfur ratio (C/S) and RE into account. The total dissolved sulfide yield was over 70% with sodium acetate as the carbon source, which was 15-20% higher than that with sodium lactate. Sodium lactate was not completely degraded and acetic acid was produced. All oxidation-reduction potential values were lower than 370 mV, indicating a perfect anaerobic condition in the BTF. The BTF could efficiently treat sulfite, sulfate, and hydrosulfite and could replace the regeneration stage of the dual-alkali process.
Author supplied keywords
Cite
CITATION STYLE
Xue, N., Wang, L., Zheng, T., Wang, J., & Wang, Q. (2015). Performance and mechanism of anaerobic biotrickling filter for removal of sulfite, sulfate, and hydrosulfite. Journal of Water Reuse and Desalination, 5(4), 528–534. https://doi.org/10.2166/wrd.2015.003
Register to see more suggestions