Study on determination of caffeine and theobromine in beverages, beverage ingredients, and pharmaceuticals by high-performance liquid chromatography with diode array detection (HPLC-DAD)

  • et al.
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

A simple and reliable analytical method for the determination of caffeine and theobromine in beverages (e.g., cola drinks, bottled tea drinks, energy drinks), beverage ingredients (e.g., cocoa powder, green coffee beans, roasted coffee, matcha powder, bagged tea), and pharmaceuticals (e.g., analgesic and antipyretic drugs) was developed and validated by using high-performance liquid chromatography with diode array detection (HPLC-DAD). The cola and energy drinks were degassed, diluted, and filtered before analysis, while a cleanup step utilizing magnesium oxide (MgO) was applied to the bottled tea drinks. The beverage ingredient samples were extracted with hot water and incorporated with MgO clean-up. The pharmaceuticals were ultrasonicated with a mixture of water/methanol (70:30, v/v). Caffeine and theobromine were completely separated on a C18 column (15 cm × 4.6 mm × 5 μm) with isocratic elution using mobile phase as water/methanol (70:30, v/v) mixture at a flow rate of 0.7 mL/min. Analytical signals of the two analytes were recorded at a wavelength of 272 nm. The instrumental method exhibited good precision (RSD < 5%), linearity (R2 > 0.999 over concentration range of 5–500 mg/L), and adequate detection limits (LOD = 1 mg/L). The entire analytical methods for different sample matrices showed acceptable recovery (89–106%) and repeatability (RSD < 5%). The validated methods were applied to analyze caffeine and theobromine in 40 real samples. In most drink and drug samples, measured concentrations of caffeine were in good agreement with label claims (bias < 10%).

Cite

CITATION STYLE

APA

Nguyen Quang, H. (2024). Study on determination of caffeine and theobromine in beverages, beverage ingredients, and pharmaceuticals by high-performance liquid chromatography with diode array detection (HPLC-DAD). Heavy Metals and Arsenic Concentrations in Water, Agricultural Soil, and Rice in Ngan Son District, Bac Kan Province, Vietnam, 7(4), 551–561. https://doi.org/10.47866/2615-9252/vjfc.4416

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free