Anaesthesia with profound hypotension for middle ear surgery

52Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

To produce a blood-free field for middle ear surgery performed with the operating microscope, the arterial systolic pressure was reduced to less than 50 mm Hg in 700 patients by means of thiopentone-halothane-nitrous oxide in oxygen anaesthesia together with pentolinium tartrate. In 84% the results were excellent, in 12% moderately good and they were poor in 4%. There were more unsatisfactory results in males (22.8%) than in females (11.4%). In spite of the arterial pressure being reduced to very low values in many instances, there was no mortality or morbidity which could be ascribed to the technique. © 1977 Copyright: Macmillan Journals Ltd.

Cite

CITATION STYLE

APA

Kerr, A. R. (1977). Anaesthesia with profound hypotension for middle ear surgery. British Journal of Anaesthesia, 49(5), 447–452. https://doi.org/10.1093/bja/49.5.447